Preparative HPLC/MPLC

- +

ACCQ Prep SFC 

 

 Green Preparative SFC: Chiral or Achiral Separations in a Single, Compact solution

         The ACCQPrep SFC is a compact system that simplifies method complexity and ensures successful separations for users of all experience levels. As the only system to enable both bulk collection from stacked injections, and multi-sample, open-access with an optional SFC AutoSampler (2x2 or 4x2), the ACCQPrep SFC offers versatility without limitations; all in the smallest Prep SFC footprint on the market.

  • Green Chromotography CO2 is affordable, environmentally friendly and reduces “strong” solvent use by up to 95%
  • Ultra Compact Do more in less space with a smaller footprint than competing systems 
  • Intuitive PeakTrak® software removes the complexity of method development

Standard Features: 

  • Flow rates from 50 to 200 mL/min for use of 2 and 3 cm columns 
  • Four different cosolvent options with composition from 5 to 70% for elution of more polar compounds than other systems 
  • Column oven with selection valve for up to six columns 
  • Autoinjector to enable multiple injections of a single sample or stacked injection workflow 
  • Choice of UV or UV-Vis PDA detectors standard
 

 Read more

ACCQ Prep SFC 

SYSTEM

Read more

Flow Rate Range 50-200 mL/min
Gradient Linearity ±1%
System Co-Solvent Range 5-70%
System Backpressure Range 100-160 bar

Maximum System 

Operating Pressure

414 bar
Mass Flow Controller Standard
Recommended Column Sizes 2 and 3 cm I.D.
Gradient Formation High pressure, dual piston reciprocating pumps
Column Selector Valve Standard; 6 columns (2 or 3 cm x 25 cm or less)
Column Oven (Temp range) Standard (+5 °C above ambient to 70 °C)
CO2 DELIVERY PUMP

 

 

CO2 Inlet Pressure 55-140 bar (3-10 °C)
Flow Rate Range 20-200 g/min
CO-SOLVENT PUMP  
Flow Rate Range 0.5-165 mL/min
Number of Co-Solvents 4 Co-Solvent Inlets
GLS Makeup Pump Standard; Automated up to 5 mL/min
SAMPLE INTRODUCTION  
Autoinjector Standard 5 mL syringe, Allows multiple injections from a single vessel
Sample Injection Modifier Stream Injection via Sample Loop (5 mL standard); other sizes may be installed and configured on the system
Stacked Injection Capability Standard
DETECTOR  
Detector Options Variable UV PDA (200-400 nm) or Variable UV-VIs PDA (200-800 nm)
SYSTEM DIMENSIONS  
Component Dimensions

Base ACCQPrep SFC: 41 x 56 x 73

SFC AS 2x2: 34 x 56 x 66

w/enclosure: 40 x 69 x 76

SFC AS 4x2: 58 x 56 x 66

w/enclosure: 64 x 69 x 76

Total System Benchtop

ACCQPrep SFC w/SFC AS 2x2 Enclosure: 81 x 69

ACCQPrep SFC w/SFC AS 4x2 Enclosure: 115 x 69

Fortune Scientific Co., Ltd.

7/25-26 Phaholyothin Rd. Anusawari,
Bang Khen, Bangkok 10220

Tel: 02-9861250-4
Fax: 02-986-1255
E-mail: sales@fortunesci.com

 