HPLC/LCMS

- +

          ChroZen UHPLC perfectly satisfies in terms of productivity and efficiency by producing the results 4~10 times faster than conventional HPLCs while ensuring both superior sensitivity and resolution. In addition, the system endures real ultra-high pressure, up to 18,800 psi (1,300 bar), with the powerful pump providing the accurate and precise flow rate by applying the concept of linear drive technology for two pairs of serially coupled pump heads, which means you can fully utilize the UHPLC columns and have the reliable data.

 

Beyond the Productivity & Efficiency

  • 4 to 10 times faster than typical runtimes on average
  • The solvent selection valve equipped in the pump allows two solvents available per pump to increase your work efficiency
  • Minimized consumption of solvents and samples

Remarkable Resolution & Sensitivity

  • Total reflection cell to maintain the intensity in optical clarity, while minimizing the system dispersion
  • The very fast data acquisition rate, 125 Hz, for the rapid data processing

More than Reliability

  • Stable, precise and accurate flow rate by truly automatic compressibility compensation
  • Dual pistons in series pump with linear drive technology
  • Lower than 0.05 % RT RSD by the precise flow rate at even the gradient mode.

High Pressure Endurability

         The longer you use UHPLC columns, the higher backpressure the system has to endure. ChroZen UHPLC endures real ultrahigh pressure, up to 18,800 psi, that utilizes the life time of UHPLC columns as long as possible.

Read more

 

Specifications

ChroZen UHPLC Pump

  • low rate: 0.001~2.000 mL/min 
  • Flow set-point: 0.001 mL/min
  • Flow precision: ≤ 0.075 % RSD
  • Pressure range: 18,800 psi (1,300 bar)
  • Solvent selection valve included (Standard)

ChroZen UHPLC Autosampler (Cool & Heat)

  • Injection range: 0~10 μL (Partial loop) 
  • RSD: < 0.5 %
  • Carry over: < 0.05 %
  • Sample capacity : 96 vials (2 ml)

ChroZen UHPLC Column Compartment

  • Temperature range: 4℃~90℃
  • Temperature stability: 0.05℃
  • Column capacity: Max. 3ea of 15 cm columns

ChroZen UHPLC FL Detector

  • Light source: 150 W Xe lamp (8.5A)
  • Wavelength range

        Ex: 200 to 850 nm

        Em: 250 to 900 nm

ChroZen UHPLC UV/Vis Detector

  • Wavelength range: 190~900 nm 
  • Data collection rate: 125 Hz
  • Noise: < ±0.5 x 10-5 AU

ChroZen UHPLC PDA Detector

  • No. of PDA channel: 1024
  • Wavelength range: 190~950 nm
  • Noise: < ±0.7 x 10-5 AU

ChroZen UHPLC RI Detector

  • Refractive Index Range: 1.00 ~ 1.75
  • Linearity: 600 μRIU
  • Noise: 5 x 10-9 RIU or less (Response : 1.5 seconds)

Read more