HPLC/LCMS

- +

          ChroZen HPLC once you define your goal and narrow down your needs such as quality of data, accuracy, and sensitivity. HPLC that delivers the most reliable data through the FlowMasterTM technology providing accurate and precise flow rate at any conditions. You can also get support next to your door by trained manpower through our worldwide network.

                 

 Reliable Evolution

  • The most accurate and precise flow rate with RT Repeatability RSD
  • Superior resolution and reproducibility through smart air circulation fulfilling perfect uniformity and stability of column temperature. (± 0.03°C)
  • Fast response time by damper-less pump design & ultra-low carryover mixing valve
  • Effective mixing in a mixing tee at forefront of pump head

Productivity Fits the Bill

  • Sufficient capacity for 30 cm columns up to 4 ea
  • Active wash for low carry-over (<0.003%)
  • Enlarged sample capacity (120 samples: 2ml vial)
  • Direct & fast injection for low sample consumption


The Various

  • Remarkable sensitivity & selectivity for any applications
  • Versatile detectors available

Sensitivity & Variety

           The most used HPLC detector, UV/Vis detector needs to be robust and sensitive enough to be utilized in various applications. ChroZen HPLC UV/Vis detector guarantees superior sensitivity and a wide dynamic range for universal detection.

Read more

Specifications

 

HPLC Column Oven

  • Room temperature within 15~25℃ and humidity 50~70%
  • Where no direct and straight sunlight
  • Plain floor without carpet, Indoor use only
  • Where having spare space of 20 cm or more
  • Where there are 10% or less voltage change, no frequency change and 100Ω or less grounding point
  • Where there is no generation of corrosive gas and ventilation is well done
  • Where stable power of 110 or 220V is supplied
  • Where not receive electromagnetic induction from large transformer, high frequency heater, UPS, etc.
  • Altitude up to 2000 m above sea level(storage within 4600m)
  • Pollution degree : 2

 

 HPLC Quaternary Pump

  • Operating principle: Parallel dual-plunger pump, Low-pressure gradient
  • Vacuum Degassing : 5 Channels (Teflon AF degassing membrane (925μL) _4 for mobile phases, 1 for pump head rinse solution
  • Compressibility compensation: Automatic
  • Flow range: 0.001-10ml/min
  • Pressure Pulsation: ≤±1% at 1ml/min (Damper-less Design)
  • Flow rate accuracy: ±1% or 10μl/min at 1ml/min, which is greater
  • Flow rate precision: ≤0.05% RSD at 1ml/min
  • Maximum pressure: 6000 psi i. Operating range: 0-6000 psi up to 5ml/min ii. Operating range: 0-3000 psi at 5~10ml/min
  • Number of eluent lines: 4
  • Gradient formation: 4-channel mixing valve
  • Composition Precision: <0.1%
  • Composition Accuracy: <0.3%
  • Automatic Rinsing: every 1 minute
  • Fully automated Prime/Purge for ready-to-use
  • Communications: LAN (LAN Cable Length : 2 m)
  • Safety & maintenance: Leak detection, Diagnostics, Error detection
  • Dimensions: 350X 180 X 580mm (width X height X depth)
  • Line Voltage: 100-250VAC
  • Line frequency: 50/60Hz 20) Power consumption: 320W

ChroZen UHPLC Column Compartment

  • Temperature range: 4℃~90℃
  • Temperature stability: 0.05℃
  • Column capacity: Max. 3ea of 15 cm columns

ChroZen UHPLC FL Detector

  • Light source: 150 W Xe lamp (8.5A)
  • Wavelength range

        Ex: 200 to 850 nm

        Em: 250 to 900 nm

ChroZen UHPLC UV/Vis Detector

  • Wavelength range: 190~900 nm 
  • Data collection rate: 125 Hz
  • Noise: < ±0.5 x 10-5 AU

ChroZen UHPLC PDA Detector

  • No. of PDA channel: 1024
  • Wavelength range: 190~950 nm
  • Noise: < ±0.7 x 10-5 AU

ChroZen UHPLC RI Detector

  • Refractive Index Range: 1.00 ~ 1.75
  • Linearity: 600 μRIU
  • Noise: 5 x 10-9 RIU or less (Response : 1.5 seconds)

 Read more

Fortune Scientific Co., Ltd.

7/25-26 Phaholyothin Rd. Anusawari,
Bang Khen, Bangkok 10220

Tel: 02-9861250-4
Fax: 02-986-1255